# Managing switch pairs In order to enable the creation of M-LAG or equivalent multi-chassis link aggregations the admins must mark the switches that form pairs. ## Create a switch pair Ensure both switches are added to the system and configured using either the UI or the `switch create` CLI command. Use the CLI to create the switch pair between switch 10 and 20: 1. List the registered switches to get the IDs: ``` metalcloud-cli switch list +-------+------------+-------------------+-------+-------------+----------+ | ID | IDENTIFIER | DATACENTER | DRIVER| PROVISIONER | MGMT IP | +-------+------------+-------------------+-------+-------------+----------+ | 4 | sw1-env2 | us12-chi-qts01-dc | os_10 | evpnvxlanl2 | 100.0.1.6 | | 5 | sw2-env2 | us12-chi-qts01-dc | os_10 | evpnvxlanl2 | 100.0.1.7 | +-------+------------+-------------------+-------+-------------+----------+ Total: 2 Switches ``` 2. Create the switch pair between the two switches ``` metalcloud-cli switch-pair create --switch1 4 --switch2 5 ``` ## Listing switch pairs To list the switch pairs to see if the switch pair was created: ``` metalcloud-cli switch-pair list +-------+---------------+---------------+-------+ | ID | Switch1 | Switch2 | TYPE | +-------+---------------+---------------+-------+ | 5 | sw1-env2 (#4) | sw2-env2 (#5) | mlag | +-------+---------------+---------------+-------+ Total: 1 Switch links ``` ## Deleting switch pairs ``` metalcloud-cli switch-pair delete --switch1 4 --switch2 5 ```