This document provides a list of features and supported generations of hardware and also a list of validated equipment. Since whenever possible we try to use standard protocals such as RedFish, IPMI and others, it is very likely that additional equipment is already be fully supported even if not listed. MetalSoft also has a streamlined process for adding new drivers for new equipment and we are adding new equipment and software versions every day. Consult with the MetalSoft team if your equipment is not on the list or a feature is required and not currently supported. We may be able to add your equipment not on the list relatively quickly.
MetalSoft supports a wide array of servers. We have tested a range of equipment but most other brands and server models should also be supported at least partially.
Both iDRAC 9 and iDRAC 8 servers are supported for both Intel and AMD.
| Feature | PowerEdge 17G | PowerEdge 16G | PowerEdge 15G | PowerEdge 14G | PowerEdge 15G |
|---|
| Power control | ✓ | ✓ | ✓ | ✓ | ✓ |
| Auto-discovery & enrollment | ✓ | ✓ | ✓ | ✓ | ✓ |
| Raid Control | ✓ | ✓ | ✓ | ✓ | ✓ |
| Firmware upgrade | ✓ | ✓ | ✓ | ✓ | ✓ |
| Remote console proxy | ✓ | ✓ | ✓ | ✓ | ✖ |
| Secure cleanup | ✓ | ✓ | ✓ | ✓ | ✓ |
| Component | Validated equipment |
|---|
| Chassis | Dell PowerEdge R660, R760, R7615, R250, R650, R750,R450, R240, R340, R740, R430, R730/xd, R230, R220, R620, C6420 |
| NICs | Intel(R) Gigabit 4P X520/I350 rNDC, Broadcom Gigabit Ethernet BCM5720, Intel(R) Ethernet 10G 2P X520 Adapter, Intel(R) Ethernet Converged Network Adapter X710, NVidia (Mellanox) ConnectX-6 Dx Dual Port 100 GbE QSFP56, Intel E810, Broadcom Gigabit Ethernet BCM5720, QLogic 25GE 2P QL41262HxCU-DE, NVIDIA ConnectX-6 Lx 2x 25G SFP28, Broadcom Adv. Dual 25Gb Ethernet |
| RAID Controllers | PERC H730 Mini, PERC 745, PERC H330, PERC H330 mini, PERC H740P, PERC H965i, BOSS S1, BOSS S2, BOSS-N1 Monolithic |
- iDRAC Enterprise (or better) license is required
- The default deployment mechanism used is Virtual Media based for all Dell Servers with the exception of 12G servers for which only the PXE mechanism is supported. Note that the PXE mechanism is deprecated and may be
removed in a later version of our software.
- iDRAC 8 minimum supported version 2.75.75.75.
- iDRAC 9 minimum supported version 5.0.0.0.
- The Serial Com port option is required for NICs that do not support SwitchConnectionView.
- Dell S1x0 series RAID controller are not supported.
All servers with ILO 7,ILO 6, ILO 5 are supported
| Feature | ProLiant Gen12 | ProLiant Gen11 | ProLiant Gen10 | ProLiant Gen9 | ProLiant Gen8 |
|---|
| Power control | ✓ | ✓ | ✓ | ✓ | ✓ |
| Auto-discovery & enrollment | ✓ | ✓ | ✓ | ✓ | ✓ |
| Raid Control | ✓ | ✓ | ✓ | ✖ | ✖ |
| Firmware upgrade | ✓ | ✓ | ✓ | ✓ | ✖ |
| Remote console proxy | ✓ | ✖ | ✖ | ✖ | ✖ |
| Secure cleanup | ✓ | ✓ | ✓ | ✓ | ✓ |
| Component | Validated equipment |
|---|
| Chassis | HPE ProLiant DL360 g10, DL380 g10, DL160 g9,DL180 g9, Dl380 g8, DL 320e/p gen8, DL 360e/p, mx710x,mx510x, XL320 |
| NICs | Ethernet 1Gb 4-port 331i +Adptr, FlexFabric 10Gb 554FLR-SFP+ FIO Adptr, Ethernet 10Gb 2P 560SFP+ Adptr |
| RAID Controllers | Smart Array P840/4G, Smart Array P408i-a SR Gen10 |
- ILO Advanced (or better) license is required for all ILO versions
- Minimum ILO version 3.11
- HPE Controllers: B1x0i are not supported.
- For Gen 12 only the Intel VROC NVMe controllers is supported
- For Gen12 the SR, MR and NS204 are not supported in versions prior to 7.0.4
- ILO5 and NVME drives directly connected to the backplane are not supported (they are not seen as disks by MetalSoft but they can still be used by the OSs)
Lenovo servers in general are all supported.
| Feature | ThinkSystem SR250, SR650 etc. |
|---|
| Power control | ✓ |
| Auto-discovery & enrollment | ✓ |
| Raid Control | ✖ |
| Firmware upgrade | ✓ |
| Remote console proxy | ✖ |
| Secure cleanup | ✖ |
| Component | Validated equipment |
|---|
| Chassis | Lenovo ThinkSystem SR250, SR650 |
Supermicro servers are generally supported though the array of hardware that Supermicro makes is very vast.
| Feature | Supermicro servers |
|---|
| Power control | ✓ |
| Auto-discovery & enrollment | ✓ |
| Raid Control | ✖ |
| Firmware upgrade | ✓ |
| Remote console proxy | ✖ |
| Secure cleanup | ✖ |
| Component | Validated equipment |
|---|
| Chassis | Supermicro ASG-1115S-NE316R |
All NX-OS switches (Nexus 9k,10k) and ACI 4.x, 5.1,5.2 platforms are supported.
| Features | Cisco NX-OS | Cisco ACI |
|---|
| OS Versions supported | 9x,10x | 4.x,5.x |
| L2 Overlay | VLAN, EVPN | EPGs |
| Gateway management | L3 SVI | Bridge Domain |
| Multi-chassis link aggregation | ✓ | ✓ |
| VFR | ✓ | ✓ |
| ACL | ✖ | ✖ |
| ZTP | ✓ (POAP) | Handled by ACI |
| Component | Validated equipment |
|---|
| Chassis | APIC 5.2 (c) with N9K-C9336C-FX2,N9K-C93108TC-FX3P, N9K-C9348GC-FXP, N9K-C9336C-FX2, N9K-C9364C, N9K-C93108TC-EX, Cisco NX-OS 10.3(3), 9.3(11) |
- Cisco Nexus: A single VRRP group is supported per interface
- Cisco Nexus: No VRRP priority is set per network device
All recent (4.x) EOS switches are supported.
| Features | Arista EOS |
|---|
| OS Versions supported | 4.x |
| L2 Overlay | VLAN, EVPN |
| Gateway management | L3 SVI |
| Multi-chassis link aggregation | ✓ |
| EVPN-Multi-homing | ✓ |
| VFR | ✓ |
| ACL | ✖ |
| ZTP | ✖ |
| Component | Validated equipment |
|---|
| Chassis | Z9664F-ON, ,Z9432-ON, S5248F-ON, S5232-ON, S5224-ON,S5212F-ON, S5248F-ON, S4148T-ON, S4128T-ON, S4048-ON |
Tomahawk-based switches do not have support for EVPN thus all EVPN related features are not supported.
All Dell Ent. SONiC and Dell OS10 equipment is supported.
| Features | Dell Ent. SONiC on Trident 3/4 | Dell Ent. SONiC on Tomahawk 4 | Dell OS10 |
|---|
| OS Versions supported | 4.x | 4.x | 10 |
| L2 Overlay | VLAN, EVPN | VLAN | VLAN, EVPN |
| Gateway management | Symmetric IRB, VRRP | VRRP | Symmetric IRB, VRRP |
| Multi-chassis link aggregation | ✓ (MCLAG) | ✓ (MCLAG) | ✓ (VLT) |
| EVPN-Multi-homing | ✖ | ✖ | |
| VFR | ✓ (for Symmetric IRB) | ✖ | ✖ |
| ACL | ✓ | ✓ | ✓ |
| ZTP | ✓ | ✓ | ✖ |
| Component | Validated equipment |
|---|
| Chassis | Z9664F-ON, ,Z9432-ON, S5248F-ON, S5232-ON, S5224-ON,S5212F-ON, S5248F-ON, S4148T-ON, S4128T-ON, S4048-ON |
Tomahawk-based switches do not have support for EVPN thus all EVPN related features are not supported.
All equipment on the Cumulus compatibility list should be supported.
| Features | Cumulus 4.2 |
|---|
| OS Versions supported | 4.x |
| L2 Overlay | VLAN, EVPN |
| Gateway management | L3 SVI |
| Multi-chassis link aggregation | ✓ |
| EVPN-Multi-homing | ✖ |
| VFR | ✓ |
| ACL | ✖ |
| ZTP | ✖ |
| Component | Validated equipment |
|---|
| Chassis | |
All Juniper equipment running Junos 18 or later is supported.
| Features | Junos 23.x | Junos 20.x | Junos 18.x |
|---|
| L2 Overlay | VLAN, EVPN | VLAN, EVPN | VLAN, EVPN |
| Gateway management | L3 SVI | L3 SVI | L3 SVI |
| Multi-chassis link aggregation | ✓ | ✓ | ✓ |
| EVPN-Multi-homing | ✓ | ✖ | ✖ |
| VFR | ✓ | ✓ | ✓ |
| ACL | ✖ | ✖ | ✖ |
| ZTP | ✖ | ✖ | ✖ |
| Component | Validated equipment |
|---|
| Chassis | Juniper qfx5100-24q-2p (Junos 20.2R3-S2.5), Junos 23.2R1.14 |
MetalSoft handles volume management,file and object storage, the storage networkm snapshots and more.
| Features | Power MAX | PowerFlex | PowerScale | PowerStore | Elastic Cloud Solutions (ECS) |
|---|
| Firmware Versions supported | PowerMaxOS 5978, 10 (6079) | 4.5+ | OneFS 9.8+ | 4.0.0.0+ | ECS 3.8+ |
| Volume management | ✓ | ✓ | N/A | ✓ | N/A |
| File share management | N/A | N/A | ✓ | N/A | N/A |
| Object storage management | N/A | N/A | N/A | N/A | ✓ |
| Snapshot Management | ✓ | ✓ | N/A | N/A | N/A |
| Protocols supported | ISCSI, FC | Proprietary, ISCSI, NVME-OF | NFS | NVMe-over-TCP, NVMe-over-FC | S3 |
| Tenant isolation at the network level | ✓ (Virtual ports) | ✓ ACL | ✓ ACL | ✓ (Virtual ports) | ✓ ACL |
| Component | Validated equipment |
|---|
| Chassis | PowerMax, PowerFlex 4.5, PowerScale F200, ECS EX3000D,PowerStore 9200T |
All NetApp equipment running ONTAP starting with version 9.6 are supported.
| Features | A250, A300, A400 | FAS2720, FAS8200 |
|---|
| Firmware Versions supported | ONTAP 9.6+ | ONTAP 9.6+ |
| Volume management | ✓ | ✓ |
| File share management | ✓ (min. OnTap 9.8) | ✓ (min. OnTap 9.8) |
| Object storage management | ✖ | ✖ |
| Protocols supported | iSCSI, NVMe-over-TCP,NVMe-over-FC,NFS | iSCSI, NVMe-over-TCP, NVMe-over-FC,NFS |
| Snapshot Management | ✓ | ✓ |
| Tenant isolation at the network level | ✓ (Virtual ports) | ✓ (Virtual ports) |
| Component | Validated equipment |
|---|
| Chassis | NetApp ONTAP 9.16.1P1 |
All Pure Storage systems using API version 2.0+ should be supported. Support added in version 7.1 of MetalSoft
| Features | FlashArray |
|---|
| Firmware Versions supported | 2.0+ |
| Volume management | ✓ |
| File share management | ✖ |
| Object storage management | ✖ |
| Protocols supported | iSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FC |
| Snapshot Management | ✓ |
| Tenant isolation at the network level | ✓ (Virtual ports) |
| Component | Validated equipment |
|---|
| Chassis | Purestorage FlashArray Purity 6.9.0 (API version 2.46) |
All Hitachi Vantara Storage Platforms are supported. Support added in version 7.1 of MetalSoft
| Features | One Block | 5000 Series | E Series | G/F Series |
|---|
| Firmware Versions supported | A3-04-2X+ | 93-07-2x+ | 90-09-2x+ | 88-08-12+ |
| Volume management | ✓ | ✓ | ✓ | ✓ |
| File share management | ✖ | ✖ | ✖ | ✖ |
| Object storage management | ✖ | ✖ | ✖ | ✖ |
| Protocols supported | iSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FC | iSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FC | iSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FC | iSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FC |
| Snapshot Management | ✓ | ✓ | ✓ | ✓ |
| Tenant isolation at the network level | ✓ (Virtual ports) | ✓ (Virtual ports) | ✓ (Virtual ports) | ✓ (Virtual ports) |
| Component | Validated equipment |
|---|
| Chassis | Hitachi VSP One B26 A3-04-21-40/00 |
| Features | Hopper PCIe Cards | Ampere PCIe cards | Turing PCIe cards |
|---|
| Detected as a component | ✓ | ✓ | ✓ |
| Used in server types | ✓ | ✓ | ✓ |
| Component | Validated equipment |
|---|
| Chassis | H100, A40, P100, T4 |