Skip to content

Compatibility matrix

This document provides information about MetalSoft compatibility with various equipment from various vendors.

MetalSoft draws the following distinction between equipment types:

  • supported equipment - equipment that MetalSoft expects to work with the software.
  • validated equipment - equipment that MetalSoft has tested in its lab.

MetalSoft maintains distinct “drivers” for different vendors (and sometimes generations of hardware and software), which lets MetalSoft cope with the different implementations of similar features across vendors.

MetalSoft supports a wide array of servers. MetalSoft has tested a range of equipment, but most other brands and server models should also be supported, at least partially.

MetalSoft performs all listed operations via the server’s OOB (management) interface.

MetalSoft supports both iDRAC 9 and iDRAC 8 servers for both Intel and AMD.

FeaturePowerEdge 17GPowerEdge 16GPowerEdge 15GPowerEdge 14GPowerEdge 13G
OS deployment✓✓✓✓✓
Power control✓✓✓✓✓
Auto-discovery & enrollment✓✓✓✓✓
Cabling detection✓✓✓✓✓
Raid Control✓✓✓✓✓
Firmware upgrade✓✓✓✓✓
Remote console proxy✓✓✓✓✖
Secure cleanup✓✓✓✓✓
ComponentValidated equipment
ChassisDell PowerEdge R660, R760, R7615, R250, R650, R750, R450, R440, R240, R340, R740, R430, R730/xd, R230, R620, C6420
NICsIntel(R) Gigabit 4P X520/I350 rNDC, Broadcom Gigabit Ethernet BCM5720, Intel(R) Ethernet 10G 2P X520 Adapter, Intel(R) Ethernet Converged Network Adapter X710, NVidia (Mellanox) ConnectX-6 Dx Dual Port 100 GbE QSFP56, Intel E810, Broadcom Gigabit Ethernet BCM5720, QLogic 25GE 2P QL41262HxCU-DE, NVIDIA ConnectX-6 Lx 2x 25G SFP28, Broadcom Adv. Dual 25Gb Ethernet
RAID ControllersPERC H730 Mgini, PERC 745, PERC H330, PERC H330 mini, PERC H740P, PERC H965i, BOSS S1, BOSS S2, BOSS-N1 Monolithic
  • MetalSoft requires an iDRAC Enterprise (or better) license.
  • MetalSoft uses Virtual Media as the default deployment mechanism for all Dell servers, except 12G servers, which support only the PXE mechanism. The PXE mechanism is deprecated, and MetalSoft may remove it in a later version of the software.
  • The minimum supported iDRAC 8 version is 2.75.75.75.
  • The minimum supported iDRAC 9 version is 5.0.0.0.
  • MetalSoft requires the Serial Com port option for NICs that do not support SwitchConnectionView.
  • MetalSoft does not support the Dell S1x0 series RAID controller.

MetalSoft supports all servers with ILO 7, ILO 6, and ILO 5.

FeatureProLiant Gen12ProLiant Gen11ProLiant Gen10ProLiant Gen9ProLiant Gen8
OS Deployment✓✓✓✓✓
Power control✓✓✓✓✓
Auto-discovery & enrollment✓✓✓✓✓
Cabling detection✓✓✓✓✓
Raid Control✓✓✓✖✖
Firmware upgrade✓✓✓✓✖
Remote console proxy✓✖✖✖✖
Secure cleanup✓✓✓✓✓
ComponentValidated equipment
ChassisHPE ProLiant DL360 g10, DL380 g10, DL160 g9,DL180 g9, Dl380 g8, DL 320e/p gen8, DL 360e/p, mx710x,mx510x, XL320
NICsEthernet 1Gb 4-port 331i +Adptr, FlexFabric 10Gb 554FLR-SFP+ FIO Adptr, Ethernet 10Gb 2P 560SFP+ Adptr
RAID ControllersSmart Array P840/4G, Smart Array P408i-a SR Gen10
  • MetalSoft requires an ILO Advanced (or better) license for all ILO versions.
  • The minimum supported ILO version is 3.11.
  • MetalSoft does not support HPE B1x0i controllers.
  • For Gen 12, MetalSoft supports only the Intel VROC NVMe controllers.
  • For Gen12, MetalSoft does not support the SR, MR, and NS204 controllers in versions prior to 7.0.4.
  • MetalSoft does not support ILO5 with NVME drives directly connected to the backplane (MetalSoft does not see them as disks, but the OSs can still use them).

MetalSoft supports Lenovo servers in general.

FeatureThinkSystem SR250, SR650 etc.
OS Deployment✓
Power control✓
Auto-discovery & enrollment✓
Cabling detection✓
Raid Control✖
Firmware upgrade✓
Remote console proxy✖
Secure cleanup✖
ComponentValidated equipment
ChassisLenovo ThinkSystem SR250, SR650

MetalSoft generally supports Supermicro servers, though the array of hardware that Supermicro makes is vast.

FeatureSupermicro servers
OS Deployment✓
Power control✓
Auto-discovery & enrollment✓
Cabling detection✓
Raid Control✖
Firmware upgrade✓
Remote console proxy✖
Secure cleanup✖
ComponentValidated equipment
ChassisSupermicro ASG-1115S-NE316R

MetalSoft offers a generic driver starting with version 7.1 of the software.

FeatureGeneric servers
OS Deployment✓
Power control✓
Auto-discovery & enrollment✓
Cabling detection✓
Raid Control✖
Firmware upgrade✖
Remote console proxy✖
Secure cleanup✖

MetalSoft supports all NX-OS switches (Nexus 9k, 10k) and ACI 6.x platforms.

FeaturesCisco NX-OSCisco ACI
OS Versions supported9x,10x5.x,6.x(6.0(3d))
L2 OverlayVLAN, EVPNEPGs
Gateway management✓✖
Multi-chassis link aggregation✓✖
VRF✓✖
ACL✖✖
ZTP✓ (POAP)Handled by ACI
ComponentValidated equipment
ChassisAPIC 6.0 (3d)
  • Cisco Nexus: MetalSoft supports a single VRRP group per interface.
  • Cisco Nexus: MetalSoft does not set a VRRP priority per network device.

MetalSoft supports all recent (4.x) EOS switches.

FeaturesArista EOS
OS Versions supported4.x
L2 OverlayVLAN, EVPN
Gateway managementL3 SVI
Multi-chassis link aggregation✓
EVPN-Multi-homing✓
VRF✓
ACL✖
ZTP✖
ComponentValidated equipment
ChassisZ9664F-ON, ,Z9432-ON, S5248F-ON, S5232-ON, S5224-ON,S5212F-ON, S5248F-ON, S4148T-ON, S4128T-ON, S4048-ON

Tomahawk-based switches do not support EVPN, so MetalSoft does not support any EVPN-related features on them.

MetalSoft supports all Dell Ent. SONiC and Dell OS10 equipment.

FeaturesDell Ent. SONiC on Trident 3/4Dell Ent. SONiC on Tomahawk 4Dell OS10
OS Versions supported4.x4.x10
L2 OverlayVLAN, EVPNVLANVLAN, EVPN
Gateway managementSymmetric IRB, VRRPVRRPSymmetric IRB, VRRP
Multi-chassis link aggregation✓ (MCLAG)✓ (MCLAG)✓ (VLT)
EVPN-Multi-homing✖✖
VRF✓ (for Symmetric IRB)✖✖
ACL✓✓✓
ZTP✓✓✖
ComponentValidated equipment
ChassisZ9664F-ON, ,Z9432-ON, S5248F-ON, S5232-ON, S5224-ON,S5212F-ON, S5248F-ON, S4148T-ON, S4128T-ON, S4048-ON

Tomahawk-based switches do not support EVPN, so MetalSoft does not support any EVPN-related features on them.

MetalSoft should support all equipment on the Cumulus compatibility list.

FeaturesCumulus 4.2
OS Versions supported4.x
L2 OverlayVLAN, EVPN
Gateway managementL3 SVI
Multi-chassis link aggregation✓
EVPN-Multi-homing✖
VRF✓
ACL✖
ZTP✖
ComponentValidated equipment
Chassis

MetalSoft supports all Juniper equipment running Junos 18 or later.

FeaturesJunos 23.xJunos 20.xJunos 18.x
L2 OverlayVLAN, EVPNVLAN, EVPNVLAN, EVPN
Gateway managementL3 SVIL3 SVIL3 SVI
Multi-chassis link aggregation✓✓✓
EVPN-Multi-homing✓✖✖
VRF✓✓✓
ACL✖✖✖
ZTP✖✖✖
ComponentValidated equipment
ChassisJuniper qfx5100-24q-2p (Junos 20.2R3-S2.5), Junos 23.2R1.14

MetalSoft handles volume management, file and object storage, the storage network, snapshots, and more.

FeaturesPowerFlexPowerScalePowerStoreElastic Cloud Solutions (ECS)
Firmware Versions supported4.5+OneFS 9.8+4.0.0.0+ECS 3.8+
Block volume management✓N/A✓N/A
File share managementN/A✓N/AN/A
Object storage managementN/AN/AN/A✓
Snapshot Management✓N/A✓N/A
QoS Management✖✖✖✖
Custom Snapshot Policy✖✖✖✖
Protocols supportedProprietary, ISCSI, NVME-OFNFSNVMe-over-TCP, NVMe-over-FCS3
Tenant isolation at the network level✓ ACL✓ ACL✓ (Virtual ports)✓ ACL
ComponentValidated equipment
ChassisPowerMax, PowerFlex 4.5, PowerScale F200, ECS EX3000D,PowerStore 9200T, PowerStore 3200 4.1.00

MetalSoft supports all NetApp equipment running ONTAP starting with version 9.6.

FeaturesA250, A300, A400FAS2720, FAS8200
Firmware Versions supportedONTAP 9.7+ONTAP 9.7+
Block volume management✓✓
File share management✓ (min. OnTap 9.8)✓ (min. OnTap 9.8)
Block Storage volume✓ (min. OnTap 9.7)✓ (min. OnTap 9.7)
Object storage management✖✖
Protocols supportediSCSI, NVMe-over-TCP,NVMe-over-FC,NFSiSCSI, NVMe-over-TCP, NVMe-over-FC,NFS
Snapshot Management✓✓
QoS Management✓ (SVM, Drive, File Share level)✓ (SVM, Drive, File Share level)
Custom Snapshot Policy✓ (SVM, Drive, File Share level)✓ (SVM, Drive, File Share level)
Tenant isolation at the network level✓ (Virtual ports)✓ (Virtual ports)
ComponentValidated equipment
ChassisNetApp ONTAP 9.16.1P1

MetalSoft should support all Pure Flash Array Storage systems using API version 2.36+. MetalSoft added support in version 7.1 and added file share management in version 7.2.

MetalSoft should support all Pure Flash Blade Storage systems using API version 2.0+. MetalSoft added support in version 7.5.

FeaturesFlashArrayFlashBlade
Firmware Versions supported2.36+2.0+
Block volume management✓N/A
File share management✓✓
Object storage management✖✓
Protocols supportediSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FC, NFSNFS, S3
Snapshot Management✓✓
QoS Management✓ (Realm, Drive level)✓ (Realm, File Share level)
Custom Snapshot Policy✓ (Protection Groups (applied to drives), File Share level)✓ (File Share level)
Tenant isolation at the network level✓ (Virtual ports)✓ (Virtual ports)
ComponentValidated equipment
ChassisPurestorage FlashArray Purity 6.9.0 (API version 2.46)
ChassisPurestorage FlashArray Purity 6.10.4 (API version 2.51)
ChassisPurestorage FlashBlade S200 Purity 4.8.2 (API version 2.26)

MetalSoft supports all Hitachi Vantara Storage Platforms. MetalSoft added support in version 7.1.

MetalSoft should also support the Hitachi WEKA Storage Platform on versions 4.1 - 4.4 and 5.0.

FeaturesOne Block5000 SeriesE SeriesG/F SeriesWeka
Firmware Versions supportedA3-04-2X+93-07-2x+90-09-2x+88-08-12+4.4.10.80
Block volume management✓✓✓✓N/A
File share management✖✖✖✖✓
Object storage management✖✖✖✖✓
Protocols supportediSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FCiSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FCiSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FCiSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FCS3, NFS
Snapshot Management✓✓✓✓✓
QoS Management✖✖✖✖✖
Custom Snapshot Policy✖✖✖✖✖
Tenant isolation at the network level✓ (IP Checks)✓ (IP Checks)✓ (IP Checks)✓ (IP Checks)✓ (IP Checks)
ComponentValidated equipment
ChassisHitachi VSP One B26 A3-04-21-40/00
ChassisHitachi Weka 4.4.10.80

MetalSoft supports Huawei OceanStor Dorado Series Storage Platforms. MetalSoft added support in version 7.2.

FeaturesOceanStor Dorado
Firmware Versions supported6.1.x, V700R001C10 and later
Block volume management✓
File share management✓
Object storage management✓
Protocols supportediSCSI, SCSI-FC, NVMe-over-TCP, NVMe-FC
Snapshot Management✓
QoS Management✖
Custom Snapshot Policy✖
VLAN Isolation✓
High Availability✓
Tenant isolation at the network level✓ (Virtual ports)
ComponentValidated equipment
ChassisOceanStor Dorado 5000 V6 V700R001C10SPC100
FeaturesHopper PCIe CardsAmpere PCIe cardsTuring PCIe cards
Detected as a component✓✓✓
Used in server types✓✓✓
ComponentValidated equipment
ChassisH100, A40, P100, T4